new France neon transformer
|
9KV 30mA the old one was the same type but was shorted and the breaker was tripped, I started with this letter "W" and switched it off then reset the breaker, the "allgreens" all stayed on, but when I switched the W back on the transformer made a loud buzz and then breaker tripped, so it was obvious at that point, I used a neon tester to verify the tubes both worked, then took the neons out and replaced the NST, after that it worked!
Also had about 10 bird nests to remove at this store, inside I had a bi-monthly to fix any interior lights, only 2 F96T8's were out , and 2 parking lot lights needed nee lamps, one also had a bad socket
|
|
One time I was in a store with every single light working perfectly not even a lense that was dirty, so I had to call my boss to ask him what I was suposed to put on the work order
Many of the older stores have the 8ft T8s the 54W lamps, but newer stores all F32T8/25W/SPX41 lamps running on 4 lamp ballasts