Gallery of Lights


Home Login
Album list Last uploads Last comments Most viewed Top rated My Favorites Search
Home > User galleries > GEsoftwhite100watts > HID Lighting
What's Wrong Here?
Guess the problem...then I will add a description and fill in the info...
Any guesses?
Keywords: Indoor_Fixtures

What's Wrong Here?

Guess the problem...then I will add a description and fill in the info...
Any guesses?

PICT0016~1.JPG PICT0184.JPG PICT0187.JPG PICT0180.JPG PICT0199.JPG
File information
Filename:PICT0180.JPG
Album name:GEsoftwhite100watts / HID Lighting
Keywords:Indoor_Fixtures
Filesize:118 KiB
Date added:Dec 29, 2012
Dimensions:640 x 480 pixels
Displayed:129 times
Color Space:sRGB
Contrast:0
DateTime Original:2003:01:01 00:00:00
Exposure Bias:0 EV
Exposure Mode:0
Exposure Program:Program
Exposure Time:1/40 sec
FNumber:f/2.8
Flash:Flash, Auto-Mode
Focal length:5.8 mm
ISO:200
Light Source:Unknown: 0
Make:Minolta Co., Ltd.
Max Aperture:f/2.8
Model:DiMAGE Z1
URL:http://www.galleryoflights.org/mb/gallery/displayimage.php?pid=14397
Favorites:Add to Favorites

Comment 1 to 7 of 7
Page: 1

streetlight98   [Dec 29, 2012 at 03:34 PM]
is it a legitimate issue or just a code violation? that splice from the white to orange cable is a violation. I'm not sure if the long length on exposed wire near the ballast is a violation, but I wouldn't strip them that far. Also there's some UGC "unidentified Green Crap" Laughing
TiCoune66   [Dec 29, 2012 at 05:28 PM]
Hmm let's see:

- No junction box
- Exposed bulb
- Spliced extension cord
- Rather doubtful hanging method (a cord... LOL)

Anything else? Laughing
GEsoftwhite100watts   [Dec 30, 2012 at 04:34 AM]
-a splice from a #14 extension cord to #12 Romex and then extension cord has a replacement plug? But maybe that's legit since the replacement plug's screws are rusted in place? I couldn't undo them either, so when I rewired it (NOTE: I didn't do the wiring you see here) I also spliced the cord until I can get a replacement plug...
Yeah, exposed bulb...doubt mine are open-rated too...but if it goes in my garage it isn't a public place and if the bulb broke/color shifted/started acting weird then I'd turn it off immediately and replace it.
It must have been hing by the rope....which I removed and will devise something else. Right now it's location is the floor.
I'll post a pic of the improved wiring...give me a minute...
A_lights   [Dec 30, 2012 at 04:38 AM]
Technically these 400W MH lamps can be burned base up or down +/- 15° , S rated meaning if turned off once a week for 15 mins then they're safe, for some reason the other lamp wattage are not rated for open use and must have a cover or internal lamp shroud
GEsoftwhite100watts   [Dec 30, 2012 at 04:49 AM]
That's what I thought...I'll have to look...
FGS   [Dec 30, 2012 at 04:52 AM]
I spy a 1Kw MV lamp in the back. Razz Laughing
GEsoftwhite100watts   [Dec 31, 2012 at 06:47 PM]
1 KW MH that is...
Is it bad to run a type "R" lamp in a non-enclosed fixture? Like it's not in a gym or anyplace where it could get broken but I wonder about UV rays escaping since it's not open-rated...am I just being paranoid?

Comment 1 to 7 of 7